Can I use a GIT-1 sensor to replace the sensor on my GIT-4 controller?
In a word: No! The GIT-1 is meant for use with the newer APS-C series controllers, EUR-5A controller and the upcoming PRO series...
Read MoreBoth the heater and supply lights are flashing on the RCU-2 remote for my GIT-4, what does it mean?
There are two possibilities and it depends on how the lights are flashing. If the lights are flashing on and off equally, that is they are...
Read MoreCan I use a GIT-4 gutter deicing controller to control external contactors?
No, using an external contactor will cause the GIT-4 to indicate a ground fault and keep it from functioning.
Read MoreHow can I test the snow sensor attached to my GIT-4 or GIT-3A gutter deice controller?
The sensors require a temperature below 38F and moisture on the moisture grid. The GIT-4 has a protruding tube that contains the...
Read MoreCan I simulate a sensor call for heat to test a GIT-4 gutter deicing controller?
Unfortunately no, the sensor and controller of the GIT-4 communicate via a data link that cannot be simulated.